Accelerator Magnet Technology Division |
5. Magnets developed for BARC Mass Spectroscopy applications:
Mass spectrometers with sector field magnetic analyzer is routinely used for the high precision & accurate isotope ratio measurements of nuclear materials. AMTD has designed and developed ten numbers of mass spectrometer analyzer dipole magnets and delivered to Technical Physics Division (TPD), BARC. Recently, two analyzer dipole magnets have been developed whose details are given below.
Parameters of Mass spectrometer analyzer dipole magnets for BARC.
Parameter
| Unit
| 200-R Dipole Magnet
| 300-R Dipole Magnet
|
Magnetic field
| Tesla
| 0-0.8
| 0-0.7
|
Pole gap
| mm
| 14
| 16.5
|
Bending radius
| mm
| 200
| 300
|
Bending angle
| Degree( o )
| 90
|
Entry angle
| 26.5
|
Exit angle
| 26.5 (± 5o)
|
Field homogeneity in good field region
| ppm
| 200
|
Good field region
| mm
| ± 20 mm (radially) from central radius and longitudinal region excluding 4 pole gaps from the entry/exit boundaries.
|
Fig. 76: DP-200R (L) & DP-300R (R) with pole edge angle adjustment mechanism.
Fig. 77: Measured radial field uniformity in DP-200R (L) and DP-300R magnets at 0.8 T field.
|
|